Reading the numbers
| Relative humidity | What it means | What to do |
|---|---|---|
| 30–50% | EPA's ideal range | Keep monitoring |
| 50–60% | Within EPA's limit | Watch seasonal peaks |
| Above 60% | Above EPA's limit | Find the source; liner, sealing, dehumidifier |
| Condensation, wet wood | Air is at its dew point on cold surfaces | Act now; check for water |
How to measure
Put a digital hygrometer in the crawl space for at least a week in the humid season and read the daily peaks, not one moment. Cold surfaces (ducts, pipes) can sweat even when the room reading looks fine.
How to lower it
- Stop liquid water: gutters, grading, drain, sump.
- Cover the ground with a sealed liner – the soil is the biggest moisture source.
- Seal vents and condition the air: dehumidifier, exhaust fan or supply air (2018 IRC R408.3).
The calculator above sizes a dehumidifier for your space; set the humidity target you want to hold.