The rule in the code
For an unvented crawl space, section R408.3 of the 2018 International Residential Code accepts, among other options, "dehumidification sized to provide 70 pints (33 liters) of moisture removal per day for every 1,000 square feet" of crawl space floor area (International Code Council, 2018 edition). Newer local codes may differ: Larimer County, Colorado (2024 IRC basis) asks for dehumidification "sized in accordance with the manufacturer's specifications" (Larimer County, Colorado – Community Development, updated Apr 28, 2026). Your building department has the final word.
Why a 70-pint unit is not 70 pints in a crawl space
Manufacturers rate capacity at 80°F and 60% relative humidity. Their own sheets show what happens in cooler air:
| Model (AprilAire) | At 80°F / 60% RH | At 73°F / 60% RH | At 65°F / 60% RH |
|---|---|---|---|
| E050 | 50 pints/day | 42 | 35 |
| E070 | 70 pints/day | 53 | – |
| E100 | 100 pints/day | 85 | – |
The E050 keeps 70% of its rating at 65°F. We use its three points as the temperature curve, so at 65°F the code's 70 pints per 1,000 sq ft becomes 100 pints of rated capacity per 1,000 sq ft. If your crawl space is warmer, move the temperature slider.
Worked example (example numbers)
1,500 sq ft crawl space at 65°F: 70 × 1.5 = 105 pints/day needed ÷ 0.70 = 150 pints/day rated → two 70-pint-class units, or one 100-pint plus one 50-pint. At 80°F the same space needs 105 pints rated – one 100-pint unit is just short.
What it costs to run
The E070 sheet lists an energy factor of 2.1 liters per kWh at 80°F. One pint (0.473 L) therefore takes about 0.23 kWh; at the U.S. average residential price of 18.17¢/kWh (U.S. Energy Information Administration, Sep 2026 data, released Nov 24, 2026) that is about 4¢ per pint removed. A dehumidifier only runs while the humidity is above its set point, so the bill depends on how much moisture gets in – which is why the liner and sealing come first.
Target: the EPA advises keeping indoor humidity below 60%, ideally 30–50% (U.S. EPA, last updated Feb 18, 2026). See the crawl space humidity level guide.